KTC 22

Interested in this product?

Please fill the inquiry form and we will get back to you at the earliest.

Categories: , Tag:

Features

1. Technology :

  • Micro controller based software technology

2. Current Range / HP :

  • 1 – 20 Amps. / 0.5 to 2 HP or as required

3. Display :

  • Digital Voltmeter (100 to 300 V)
  • Digital Ammeter (1 – 30 Amps. / as required)

4. Protections :

  • Electronic Overload (Site Settable)
  • Remote Sensing Dryrun (Site Settable)
  • High / Low Voltage(Site Settable)
  • Extreme High Current(Short Circuit)

5. Special Feature :

  • Two tank Fully Automatic Universal Water Level Controller Auto Start On Power Failure
  • Pressure Switch Connection Facility Available
  • Float Bypass Facility Available

6. Timers : 

  • Power On Timer
  • Dryrun Auto Start Timer ( Off – 5 – 720 mins.)

7. Capacitors : 

  • Running Capacitor – One (max. 60 Mfd )

Specifications

1. System Settings

• Input Voltage (AC) : 140 – 290 VAC, 50 Hz
• On voltage (cold start) : Minimum 140 VAC ± 5 VAC
• Auto Off voltage : At 125 VAC ± 5 VAC

2. Protections / Setting Parameters

• Protection Design : Current Sensing
• Pump Current Range : 1 – 20 Amps or as required
Sr. No. Parameter Setting Range Default setting Trip Time Delay Display LED
1 Overload 20% – 60% > 140 % 15 sec YES YES
2 Dryrun 60% – 95% < 75 % 15 sec YES YES
3 High Voltage 250 – 300 280 V ± 2 V Fixed HIU YES
4 Low Voltage 110 – 180 V 140 V ± 2 V Fixed LOU YES
5 Extremely High Current Fixed Fixed 3 sec EHC YES

3. Timers

Sr. No. Parameter Setting Range Default setting Display LED
1 Power ON Timer 3 sec – 300 sec 60 sec ± 3 sec PONT YES
2 Dryrun Autostart Timer 5 – 720 min OFF OFF YES

4. Reset

• Resetting mode : Manual by OFF switch

5. Output Relay Contact

• Relay Mechanical life : 10 lac operations
• Dielectric Strength : 2.2 KV , 50 Hz for 1 min

6. Enclosure & Mounting

• Enclosure Material : Rust Proof, Shock Proof, Industrial  ABS Enclosure
• Mounting : Wall Mounting with 4 screw M4 × 15 mm
• Temperature : 5 to 60°C
• Humidity : Upto 90% RH

7. Dimensions & Weight

• L × W × D (mm) : × × mm
• Power Consumption : Less than 5 Watts
• Weights : gms.

Options

 1. Model :

A. KTC 22 WLC with PN Input and PN Output

B. KTC 22 WLC with PN Input and RYB Output

2. Capacitors  & HP :

 36  MFD  1 HP
 50 MFD  2 HP
 60 MFD  3 HP

 

Applications

  • Agriculture
  • Irrigation
  • Domestic

Connection Diagram

KTC 22 WLC with PN Input and RYB Output :

INPUT OUTPUT UPPER TANK LOWER TANK
P N R Y B P1 P2 P3 P1 P2 P3

 

Download Manual

Download Manual

Reviews

There are no reviews yet.

Be the first to review “KTC 22”

Your email address will not be published. Required fields are marked *