GSM DRYRUN

Interested in this product?

Please fill the inquiry form and we will get back to you at the earliest.

Categories: , Tag:

Features

1. Technology :

  • Micro controller based software technology

2. Current Range / HP :

  • 2 – 60 Amps.

3. GSM Features :

  • Stop / Stop / Monitor / Set your motor from any phone
  • Talks Online in Local Language
  • Add Four Authorized Users
  • SMS based Realtime reports
  • Online Parameter Settings by SMS
  • Hour Meter, Total Hour Meter, Auto Lift, Auto Cut
  • Site Settable Four Digit Password with SIM Tracking
  • Missed Call based ON / OFF
  • Web Based Android Application
  • Receive Phone Call for Fault & Power Return (Call Back)
  • Select Auto / Manual Mode by Phone Call
  • Verbal Voltage & Current Information on Phone Call

5. Protections :

  • Phase Failure (Supply Side)
  • Reverse Phase (Supply Side)
  • Voltage Unbalance
  • Remote sensing Dryrun (Site Settable by SMS)

5. Timers : 

  • Power On Timer For Auto start (Site Settable)
  • Dryrun Auto Start Timer OFF – 5 – 720 mins. (Site Settable)
  • Star Delta Timer (Site Settable)

 

 

Specifications

1. System Settings

• Input Voltage (AC) : 250 – 470 VAC, 50 Hz
• On voltage (Cold Start) : 250 VAC
• Auto Off voltage : 200 VAC

2. Protections / Setting Parameters

• Pump Current Range : 2 – 60 Amps.
Sr. No. Parameter Setting Range Default setting Trip Time Delay LED
1 Phase Failure Fixed Fixed 4 sec ± 1 sec YES
2 Reverse Phase Fixed Fixed 4 sec ± 1 sec YES
3 Voltage Unbalance Fixed Fixed 4 sec ± 1 sec YES
4 Overload 20% – 60% > 140 % 15 sec NO
5 Dryrun 60% – 95% < 75 % 15 sec YES

3. Timers

Sr. No. Parameter Setting Range Default setting LED
1 Power ON Timer 3 sec – 300 sec 60 sec ± 3 sec NO
2 Star Delta Timer 3 sec – 300 sec 10 sec ± 2 sec NO
3 Dryrun Auto Start Timer 5 – 720 min OFF NO

4. Reset

• Resetting mode : Manual by OFF switch

5. Output Relay Contact

• Relay Mechanical life : 10 lac operations
• Dielectric Strength : 2.2 KV , 50 Hz for 1 min

6. Enclosure & Mounting

• Enclosure Material : Rust proof, Shock Proof, ABS Enclosure
• Mounting : Wall Mounting with 4 screw M4 × 15 mm
• Temperature : 5 to 60°C
• Humidity : Up to 90% RH

7. Dimensions & Weight

• L × W × D (mm) :  x  x  mm
• Power Consumption : Less than 5 Watts
• Weights :  gms.

 

Application

  • Agriculture
  • Irrigation
  • Domestic

Connection Diagram

INPUT 415 VOLT NO VOLT COIL ACROSS ON BUTTON
R Y B N V S1 S2

Download Manual

Download Manual

Reviews

There are no reviews yet.

Be the first to review “GSM DRYRUN”

Your email address will not be published. Required fields are marked *