QuickContact
+91-9637440777 |
HOME ABOUT US PRODUCTS PHOTOS DOWNLOADS CONTACT US LOGIN
Our Product
Our Models
Products I Pump Control panels I kdp 22 ds
  • Features & Protections
  • Indications & displays
  • Enclosures & Mounting
  • Options
  • Specifications
Features & Protections
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
Graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
Technology
Microcontroller based digital product with high reliability and long life.


World class MCU and software which is highly fault tolerant to noise and Electro magnetic interferences and noise from motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings
Pump current setting is easy, accurate, auto setting type, with digital display.

Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Monitoring
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volt. Accuracy.

Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
In built memory to show last setting value.
On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers
Digital display for countdown timer.

Time delay to filter power on spikes and surges.
Capacitor cut off timer to protect starting capacitor.
Additional Features
Starting (1) and running capacitors (2) as per pump requirements.

Site selectable auto / manual operation facility.
Widest working voltage range from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps dc coil contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.
Emergency bypass for water level controller.
Indications & Displays
Auto scrolling display for updated pump current and line voltage.
Ultra bright indicators for all faults.
Early fault warnings by blinking LED.
Value of tripping current / voltage.
Setting / pump on.
Overload.
Dry run.
Capacitor cut off timer.
Short Circuit.
Enclosures & Mountings
Compact, vermin proof, rust proof, powder coated mild steel panel box.
Size : 245 x 245 x 105 mm.
Weight : 2989 gms.
Mounting : wall.
Options
Starting (1) and running capacitors (2) as per pump requirements.
100 / 125 + 25 MFD 0.75 / 1 H.P.
120 / 150 + 36 MFD 1.0 H.P.
120 / 150 + 36 + 20 MFD 1.5 H.P.
120 / 150 + 36 + 36 MFD 2.0 H.P.
150 / 200 + 36 + 36 MFD 2.0 H.P.
250 / 200 + 36 + 36 MFD 2.0 / 3.0 H.P.
Technical Specifications
Input Voltage (AC) 160-275 VAC, 50 Hz
On voltage Minimum 160 VAC +/- 5VAC
Off voltage At 140 VAC +/- 5VAC
Output Contact Rating on 230 VAC 1 NO, 40 Amp (resistive)
Protection Design
Current Driven
Pump Current setting Scale 2 - 14 amp site settable
Dry run setting range 75% to 95% +/- 2% site settable
Protections
  1 Overload 140% +/- 10% of set current
   Trip time delay 15 sec+/- 2 sec
  2 Dryrun / No load current Fixed at 75 % of set current
   Trip time delay 15 sec+/- 2 sec
  3 Starting capacitor cut off timer 5 sec 1 sec
Indications
Pump ON / Setting Yes
Short Circuit Yes
Starting capacitor cut off timer Yes
Overload Yes
Dryrun Yes
Ultra Bright 7 Segment 3 Digit Display shows following parameters
Digital Voltmeter ( calibrated ) 100 to 300+/- 2 Volt
Digital Ammeter ( calibrated ) 0.5 to 24 Amps
Overload OL
Dryrun DRA
Capacitor cut off timer CCT
Short circuit at 26 amps EHC
Pump ON ON
Pump OFF OFF
Reset at Fault RESET
Starting capacitor ( one no) As per pump requirement
Running capacitor ( one or two nos) As per pump requirement
Reseting mode Manual by off switch
Relay Mechanical life 10 lac operations
Dielectric Strength 2.2 KV , 50 Hz for 1 min
Enclosure Material Rust proof,Powder coated mild steel panel box
Mounting Wall mounting with 4 screw M4 x 15 mm
Temperature
5 to 60 C
Humidity
upto 90% RH
Dimensions (LxWxD) mm
245x245x105 mm
Power consumption
less than. 5 Watts
Weight (gms) 2989 gms

Pump control panels and starters
With start and run capacitors
KDP 22 DS
KDP 99 WLC
KSR 22
KSD 22
With only running capacitors
KTC 33 WLC (Digital)
KSP 22
KTC 22
TC 22
Single phase starter
SS 22
DOL SERIES
KDM 216 CS
KDM 2-30 panel
KTP 99 DRA
KSI 33 MCB
KSI 33 MINI
START DELTA SERIES
Star delta panels
         
Home About Us Products Mobile Starters & Panels Downloads
About Us Management Pump control panels and starters Mobile starter with external phone Khyatee Mobile Starter English
Products Vision & Mission Mobile starters and panels KMS 33 Khyatee Mobile Starter Marathi
Products Gallery Value Statement GSM- wireless monitor and control KMS Mini M3 Khyatee Mobile Starter M3 Unit
Downloads Quality Policy Medical Products M3 Unit Mobile Starter Manual
Contact Us Milestones Hydro pneumatic automation Mobile Starter Chart  
Facebook Accreditations Liquid level automation    
You Tube Why Khyatee Domestic home care series Mobile Starter with inbuilt GSM SIM  
    Energy management M4 Display SIM  
    Water / RO plant automation M5 GSM LCD  
    Phase failure relays    
    Timers    
2012 All Rights Reserved.   Powerd by :: Cosmic ::