Khyatee GSM Wireless

The "KHYATEE GSM WIRELESS MOTOR MANGEMENT" is intelligent and flexible motor management system. It offers comprehensive motor management including extensive protection, monitoring and control functions. With easy to use operation and on-site diagnostic data helps us to carry out predictive maintenance and GSM Technology based operation.


This has Dual core microcontroller and GSM SIM based technology which is unique, reliable, and cost effective and continues to monitors all parameter and applications simultaneously at all the time and there is no delay in any fault condition detection, monitoring and providing safety.

The KHYATEE GSM / GPRS BASED WIRELESS DATALOGGER is a complete, ready-to-integrate, embedded GSM based wireless platform. Designed for global use, it offers international standards based multi-band GSM/GPRS Class 10. This quick-to set parameters allows users to add wireless communication to products with a minimum of development time and expense.


• GPRS Class 10
• Dual-band 850/1900 or 900/1800 MHz GSM/GPRS
• Packet data up to 85K bps
• Embedded TCP/IP stack
• Circuit-switched data (GSM) up to 14.4K bps transparent and nontransparent
• GSM Class 1 and Class 2 Group 3 Fax
• Short Message Services (SMS)
• MMCX antenna connector and SIM socket
• Serial interface supports DTE speeds to 115.2K bps
• AT command compatible
• MNP 2 error correction, V.42bis compression
• Universal socket connectivity

Mobile Phone and SIM Based Operations

This product is very unique as you can three modes to operate .

1. Use switches given on the unit
2. Dial the GSM SIM card inserted in the unit and use voice interactive service.
3. By sending SMS to unit to do /set all the parameters.

Khyatee GSM data logger uses activated SIM card from any GSM service provider which communicate with server or any mobile phone.

For example system is installed and connected to motor than it continuously monitors/ protects every activity of motor at site and sends all data to the web server / website or any mobile phone by SMS on real time basis.


This has CURRENT SENSING technology so motor is 100% protected up to MOTOR terminals.

Phase failure / loss from supply and motor side.

Phase reversal / wrong phase sequence from supply side.
Phase to phase current unbalance ( site selectable).
Electronic overload ( site selectable).
Remote sensing dry run / No load current ( site selectable).
Extreme high current (EHC) or short circuit.
Control Settings

PUMP CURRENT SETTING is easy, accurate, auto setting type, with digital display.

Pump current setting can be done through SMS, Mobile phone & onsite.
Overload is site selectable from 20 to 50 % of set current.

Dry run setting from 75 to 95 %.
Dry run bypass facility with Digital Display.

Site selectable Auto / Manual operation switch.
Monitoring on LCD
Calibrated Digital Voltmeter with ± 2V Accuracy.

Calibrated Digital Ammeter ± 0.2Amp Accuracy.
Scrolling Ammeter for R, Y, B, Phases average current.

Digital display for fault value at tripping.
Inbuilt memory to show last setting value.

On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.

Clock (RTC) based 4 ON and 4 OFF timers for system automation.

Site settable auto start timer for power failure (3-300 secs) and SPP faults from supply side.
Site settable star delta timer (3-30 secs.)

Site settable dry run auto start timer (10-720 min).
Time delay to filter power on spikes and surges

Cyclic timer for on off operations from 10-720 min (site selectable).
Digital display for countdown timer.
Additional Features
Suitable for DOL, Star-Delta Starters up to 500HP.

4 Digit Password protected operation.
Talks 40 verbal information in required language.

Works on wide voltage supply (90 to 500 V).

Facility to check network communication between GSM SIM and dialer phone.

No call charges when power is absent.

Auto call disconnect facility to save call charges.

Motor ON and OFF switch on unit.

Switch for Easy bypass and network checking.
Indications & Displays
Auto scrolling display for updated pump current and line voltage.
Display for average pump current phase wise.
Early fault warnings by blinking LED.
Value of tripping current / voltage.
Healthy Condition.
Pump ON.
SMS Facility

Most unique facility of this product is all following many things can be done or much information can be received by SMS…to 4 predefined mobile phone numbers in the unit. To register the data recipients number just send SMS to unit and now you can do all following things ……

Send SMS

To add phone number of data recipient.
To delete phone number of data recipient.
To switch on the motor.
To switch off the motor.
To reset the fault.
To activate the SMS facility.
To deactivate the SMS facility.
To get help menu.
Detail status report will tell you actual site condition and 8 parameters.
To get SMS list of registered recipients phone number.
To change the 4 digit password.
To enable password protection, Ask password when we call the unit.
To disable password protection, don't ask password when we call the unit.
To set pump current by SMS.
To set overload current percentage from 20% to 50%.
To set dry run percentage from 60% to 95%.
To bypass the dry run.
To set current unbalance percentage from 20% to 70%.
To bypass current unbalance.
To set star delta timer from 3 to 30 seconds.
GET IMEI number of SIM CARD.
Get phone number which called the unit.
Get new number if SIM card changed ( SIM TRACKER).
Web Based Data Reports ( Optional )

Again we can provide all motor related data and variety of reports on web. Few of them are listed below.

You get motor on time report.
You get motor off time report.
You get power failure time report.
You get motor off due to fault report.
You get fault report with time.
You get motor theft protection at site.
You get motor disconnection report.
You get Hour meter.
Enclosures & Mountings
Compact, vermin proof, rust proof engineering plastic box.
Size : 220 x 175 x 75 mm
Weight : 850 gm (approx).
Mounting : wall.
Model - M4 GSM Without digital display all data by SMS.
Model - M5 GSM LCD with RTC based timer etc.
Model - M6 GSM LCD with WEB Based Datalogger…etc.

Model M2 – with automatic change over for 2 phase based operation with mobile phone based 2 or 3 phase operation and trip seeting protection for 2 phase based operations. And much more…

Mobile Starters and Panels
KMS 33
KMS Mini M3
M3 Unit
Mobile Starter Chart
M4 Display SIM
Home About Us Products Mobile Starters & Panels Downloads
About Us Management Pump control panels and starters Mobile starter with external phone Khyatee Mobile Starter English
Products Vision & Mission Mobile starters and panels KMS 33 Khyatee Mobile Starter Marathi
Products Gallery Value Statement GSM- wireless monitor and control KMS Mini M3 Khyatee Mobile Starter M3 Unit
Downloads Quality Policy Medical Products M3 Unit Mobile Starter Manual
Contact Us Milestones Hydro pneumatic automation Mobile Starter Chart  
Facebook Accreditations Liquid level automation    
You Tube Why Khyatee Domestic home care series Mobile Starter with inbuilt GSM SIM  
    Energy management M4 Display SIM  
    Water / RO plant automation M5 GSM LCD  
    Phase failure relays    
2012 All Rights Reserved.   Powerd by :: Cosmic ::